This product is for Professional Use only and not for sale to the general public for home use.
Please log in with a business account to purchase.

Direct Conjugated Bilirubin Assay 0.4-20 mg/dL serum plasma vanadate oxidation method liquid clinical chemistry analyser Reagent 2 FUJIFILM Wako
Product code: 996-24191
Pack Size: 4x18ml
CE Verification: IVDR
- List Price
- £161.67
Product Information
Direct Bilirubin (L-Type) Assay Reagent 2 manufactured by FUJIFILM Wako Pure Chemical Corporation.
Direct Bilirubin is an in vitro assay for the quantitative determination of direct (also known as conjugated) bilirubin (D‑Bil) in serum or plasma, and is designed to be applied to general clinical chemistry analysers. Measurement of D‑Bil concentration is widely used as a screening test for liver functions in medical checkups or in patients with liver disease. The usage and application of this reagent is reserved for professional use only.
Bilirubin measurement is widely used as a screening test for liver functions. The methods most widely used for determination of bilirubin are the diazo coupling and the bilirubin oxidase enzymatic methods. However, these methods have disadvantages such as interferences by coexistent substances and unsatisfactory stability of reagents after preparation. FUJIFILM Wako’s Direct Bilirubin assay is based on a chemical oxidation method, utilizing vanadate as an oxidizing agent. It shows good correlation with these conventional methods; practically no interference by coexistent substances; and is supplied as convenient ready‑to‑use liquid reagents.
FUJIFULM Wako Direct Bilirubin is a vanadate oxidation method that demonstrates good correlation with traditional diazo coupling and bilirubin oxidase methods and is unaffected by ascorbic acid (up to 50mg/dL) and haemoglobin (500mg/dL). The assay is suitable for use with serum and plasma samples. When the sample is mixed with the Direct Bilirubin reagents, the vanadate oxidises yellow bilirubin in the sample to green biliverdin. Therefore, by measuring the change in absorbance at 450nm and the concentration of direct bilirubin in the sample can be calculated. The assay range is 0.4 - 20 mg/dL and the ready-to-use reagents have an open vial stability of up to 1 month when stored as directed.
The FUJIFILM Wako Direct Bilirubin assay reagents are supplied individually. This product code relates to Direct Bilirubin Reagent 2 only. Direct Bilirubin Reagent 1 (990-24091) and Bilirubin Calibrator (994-24491) are sold separately.
Direct Bilirubin (L-Type) Reagent 2 4x18ml
Ready to use reagent.
Store at 2-35C, OVS 1 month.
Direct Bilirubin is an in vitro assay for the quantitative determination of direct (also known as conjugated) bilirubin (D‑Bil) in serum or plasma, and is designed to be applied to general clinical chemistry analysers. Measurement of D‑Bil concentration is widely used as a screening test for liver functions in medical checkups or in patients with liver disease. The usage and application of this reagent is reserved for professional use only.
Bilirubin measurement is widely used as a screening test for liver functions. The methods most widely used for determination of bilirubin are the diazo coupling and the bilirubin oxidase enzymatic methods. However, these methods have disadvantages such as interferences by coexistent substances and unsatisfactory stability of reagents after preparation. FUJIFILM Wako’s Direct Bilirubin assay is based on a chemical oxidation method, utilizing vanadate as an oxidizing agent. It shows good correlation with these conventional methods; practically no interference by coexistent substances; and is supplied as convenient ready‑to‑use liquid reagents.
FUJIFULM Wako Direct Bilirubin is a vanadate oxidation method that demonstrates good correlation with traditional diazo coupling and bilirubin oxidase methods and is unaffected by ascorbic acid (up to 50mg/dL) and haemoglobin (500mg/dL). The assay is suitable for use with serum and plasma samples. When the sample is mixed with the Direct Bilirubin reagents, the vanadate oxidises yellow bilirubin in the sample to green biliverdin. Therefore, by measuring the change in absorbance at 450nm and the concentration of direct bilirubin in the sample can be calculated. The assay range is 0.4 - 20 mg/dL and the ready-to-use reagents have an open vial stability of up to 1 month when stored as directed.
The FUJIFILM Wako Direct Bilirubin assay reagents are supplied individually. This product code relates to Direct Bilirubin Reagent 2 only. Direct Bilirubin Reagent 1 (990-24091) and Bilirubin Calibrator (994-24491) are sold separately.
Direct Bilirubin (L-Type) Reagent 2 4x18ml
Ready to use reagent.
Store at 2-35C, OVS 1 month.
Specification
- Brand FUJIFILM Wako Chemicals Europe GmbH – Diagnostics
- Sterile N
- CE Certified IVDR
- Warranty Period Standard Terms Apply
- Sterilisation Method Not Applicable
- Is product classified as dangerous goods? No
- Does the product contain latex? Unspecified
- CAS Number NULL
- Composition Liquid stable, dual reagent system R2 Set
- Concentration 0.04 – 20 mg/dL.
- Detection Method Colorimetric
- Diagnostic Target Serum or plasma direct conjugated bilirubin
- Form 4x18ml
- Marketed Grade IVD CE
Storage Details
- Pack Description 4x18ml
- Shipping Condition Blue Ice
- Storage Condition Fridge
- Storage Conditions (Max Temp) 35
- Storage Conditions (Min Temp) 2
- Pack Length (m) 0.1
- Pack Width (m) 0.1
- Pack Height (m) 0.1
- Pack Weight (kg) 0.15