This product is for Professional Use only and not for sale to the general public for home use.
Please log in with a business account to purchase.

Extel Hemo Auto NE Latex-Buffer
Product code: 066100
Pack Size: 4x14ml+4x50ml
CE Verification: IVDR
Product Information
These EXTEL HEMO AUTO NE Latex and Buffer reagents are highly sensitive, for use on the HM-CODIAM Faecal Immunochemical Testing (FIT) analyser, to quantify the amount of haemoglobin in faeces.
Background:
Blood in faeces could be a symptom of a range of gastroenterological complaints: colorectal cancer (CRC), inflammatory bowel disease (IBD), and diverticular disease, for example. The use of a marker such as blood in the stool has been used for CRC screening programmes for over 10-years, originally with a guaiac based, qualitative technology, referred to as faecal occult blood (gFOB).
Quantitative faecal immunochemical testing on bench top analysers such as the HM-CODIAM are now used in symptomatic referral and screening programmes, to help triage patient care appropriately, identify bowel cancer earlier, and improve laboratory workflow.
The assay on the HM-CODIAM analyser utilises photometric absorbance to accurately determine the concentration of haemoglobin in faeces. The latex molecules are coated in an excess of polyclonal antibodies specific to human haemoglobin, ensuring even very high results are not artificially reported low. The assay has a wide, linear, range of 7-400 ng/mL faeces, and a limit of detection of 2.8 ng/mL faeces. Being specific to human haemoglobin there are no dietary restrictions required prior to sampling. Each lot of reagent has a factory-set reaction response master curve, which is confirmed by performing a local 2-point recalibration.
Product Specification:
One pack contains 4 x 14ml bottles of Latex and 4 x 50ml bottles of Buffer
One 14ml bottle of latex and one 50ml bottle of buffer is suitable for performing 200 tests
Each pack of Latex is provided with a Master Curve data barcoded label.
Handling and Storage:
Store in a cool, dark, place at 2 - 8 C – do not freeze.
Shelf Life – 12 months from Manufacturing
The onboard stability is 20 accumulated hours (reaction must occur at room temperature), and open bottle stability when refrigerated (2 - 8 C) is until expiry date.
Background:
Blood in faeces could be a symptom of a range of gastroenterological complaints: colorectal cancer (CRC), inflammatory bowel disease (IBD), and diverticular disease, for example. The use of a marker such as blood in the stool has been used for CRC screening programmes for over 10-years, originally with a guaiac based, qualitative technology, referred to as faecal occult blood (gFOB).
Quantitative faecal immunochemical testing on bench top analysers such as the HM-CODIAM are now used in symptomatic referral and screening programmes, to help triage patient care appropriately, identify bowel cancer earlier, and improve laboratory workflow.
The assay on the HM-CODIAM analyser utilises photometric absorbance to accurately determine the concentration of haemoglobin in faeces. The latex molecules are coated in an excess of polyclonal antibodies specific to human haemoglobin, ensuring even very high results are not artificially reported low. The assay has a wide, linear, range of 7-400 ng/mL faeces, and a limit of detection of 2.8 ng/mL faeces. Being specific to human haemoglobin there are no dietary restrictions required prior to sampling. Each lot of reagent has a factory-set reaction response master curve, which is confirmed by performing a local 2-point recalibration.
Product Specification:
One pack contains 4 x 14ml bottles of Latex and 4 x 50ml bottles of Buffer
One 14ml bottle of latex and one 50ml bottle of buffer is suitable for performing 200 tests
Each pack of Latex is provided with a Master Curve data barcoded label.
Handling and Storage:
Store in a cool, dark, place at 2 - 8 C – do not freeze.
Shelf Life – 12 months from Manufacturing
The onboard stability is 20 accumulated hours (reaction must occur at room temperature), and open bottle stability when refrigerated (2 - 8 C) is until expiry date.
Specification
- Brand Canon Medical Diagnostics Corporation
- Sterile N
- CE Certified IVDR
- Warranty Period Standard Terms Apply
- Sterilisation Method Unspecified
- Is product classified as dangerous goods? No
- Does the product contain latex? Unspecified
- UK CA Type IVDR
Storage Details
- Pack Description 4x14ml+4x50ml
- Shipping Condition Blue Ice
- Storage Condition Fridge
- Storage Conditions (Max Temp) 8
- Storage Conditions (Min Temp) 2
- Storage Conditions (Humidity) 40
- Pack Length (m) 0.117
- Pack Width (m) 0.058
- Pack Height (m) 0.0925
- Pack Weight (kg) 0.40