PYROSTAR ES-F/Plate Multi Test Endotoxin Testing Kit w/Control Standard Endotoxin (CSE) KTA Sensitivity 0.01-10 1 pack 4x2mL for use with microplates
Product code: WPEPK4-20015
Pack Size: 4x2mL
CE Verified: Research Use Only
Contact us
This is not a regular stock item and therefore not subject to our standard delivery schedule. Please contact us on +44 (0) 2380 483000 for advice on expected delivery date.
Product Information
PYROSTAR is Fujifilm Wako’s range of endotoxin testing instruments and reagents, based on the Limulus Amoebocyte Lysate (LAL) assay.
The LAL assay operates using lysate isolated from the blood of the Atlantic Horseshoe Crab (Limulus polyphemus). When exposed to bacterial endotoxins, generally arising from lipopolysaccharides (LPS) in the bacterial cell wall, these lysates coagulate and in turn cause the crab’s blood to clot. The Pyrostar LAL assay harnesses this process to provide the most sensitive endotoxin detection method approved by the FDA.
This PYROSTAR ES-F/Plate Endotoxin Testing Kit provides 4 2mL vials of PYROSTAR ES-F lyophilised reagent for use with microplates. Each vial allows for multiple microplate tests using the Kinetic Turbidimetric Assay (KTA) method, with an endotoxin sensitivity of 0.01-10EU/mL.
Kinetic Turbidimetric Assay (KTA) Method
The KTA method, when used with microplates, is a quantitative method for detection of bacterial endotoxins, using a photometric instrument, in this case a microplate reader. The assay works using the same coagulation principle as the GCA method, however by using a microplate reader to measure sample turbidity the speed of coagulation can be determined and through regression analysis in comparison to a standard curve, the toxinometer will calculate the sample endotoxin level.
Pack Contents:
4 vials ES-F Reagent
•Reconstitution: Ensure all lysate is at bottom of vial by knocking on a hard surface and add 2mL of LAL Reagent Water (LRW) (Not included).
•Storage (Unreconstituted): 2-10°C
•Storage (Reconstituted): 2-8°C (≤4 hours), -15°C (≤14 days)
Not Included (Product Code(s) where available):
•Control Standard Endotoxin (CSE) (CSE4037-5006)
•Reference Standard Endotoxin (RSE): USP Endotoxin Reference Standard with potency of 10,000 USP Endotoxin Units (EU)
•LAL Reagent Water (LRW) (12x100mL LRW-12100, 20x30mL LRW-2030, 12x125mL LRW-12125)
•Endotoxin free pipette tips (200µL 291-35021, 1mL 298-35031, 200µL Ext 294-35011)
•Endotoxin free microplates (293-35221)
•Microplate reader
•Water Bath
The LAL assay operates using lysate isolated from the blood of the Atlantic Horseshoe Crab (Limulus polyphemus). When exposed to bacterial endotoxins, generally arising from lipopolysaccharides (LPS) in the bacterial cell wall, these lysates coagulate and in turn cause the crab’s blood to clot. The Pyrostar LAL assay harnesses this process to provide the most sensitive endotoxin detection method approved by the FDA.
This PYROSTAR ES-F/Plate Endotoxin Testing Kit provides 4 2mL vials of PYROSTAR ES-F lyophilised reagent for use with microplates. Each vial allows for multiple microplate tests using the Kinetic Turbidimetric Assay (KTA) method, with an endotoxin sensitivity of 0.01-10EU/mL.
Kinetic Turbidimetric Assay (KTA) Method
The KTA method, when used with microplates, is a quantitative method for detection of bacterial endotoxins, using a photometric instrument, in this case a microplate reader. The assay works using the same coagulation principle as the GCA method, however by using a microplate reader to measure sample turbidity the speed of coagulation can be determined and through regression analysis in comparison to a standard curve, the toxinometer will calculate the sample endotoxin level.
Pack Contents:
4 vials ES-F Reagent
•Reconstitution: Ensure all lysate is at bottom of vial by knocking on a hard surface and add 2mL of LAL Reagent Water (LRW) (Not included).
•Storage (Unreconstituted): 2-10°C
•Storage (Reconstituted): 2-8°C (≤4 hours), -15°C (≤14 days)
Not Included (Product Code(s) where available):
•Control Standard Endotoxin (CSE) (CSE4037-5006)
•Reference Standard Endotoxin (RSE): USP Endotoxin Reference Standard with potency of 10,000 USP Endotoxin Units (EU)
•LAL Reagent Water (LRW) (12x100mL LRW-12100, 20x30mL LRW-2030, 12x125mL LRW-12125)
•Endotoxin free pipette tips (200µL 291-35021, 1mL 298-35031, 200µL Ext 294-35011)
•Endotoxin free microplates (293-35221)
•Microplate reader
•Water Bath
Specification
- Brand FUJIFILM Wako Chemicals Europe GmbH – Lab Chem
- Sterile Y
- CE Certified Research Use Only
- Warranty Period Standard Terms Apply
- Is product classified as dangerous goods? No
- Does the product contain latex? Unspecified
- Detection Type Limulus Amebocyte Lysate (LAL) Assay
- Contents 4 x 2mL PYROSTAR ES-F Multi-Test Vials (Sensitivity 0.01-10EU/mL)
1 Vial 500ng Control Standard Endotoxin - Specificity Bacterial Endotoxin
- Time Required 1 Hour
- Application Bacterial Endotoxin Testing
Storage Details
- Pack Description 4x2mL
- Shipping Condition Blue Ice
- Storage Condition Fridge
- Pack Length (m) 0.1
- Pack Width (m) 0.2
- Pack Height (m) 0.1
- Pack Weight (kg) 0.00