Heater Dry Block programmable ThermoQ for 0.5ml tubes heating and cooling unit for molecular biology incubation applications
Product code: TC2610
Pack Size: Each
CE Verified: CE Electrical
Product Information
The Thermo Q dry block heater for 0.5ml tubes features innovative hardware including a pressure hot-lid design to avoid evaporation when running. The hot-lid temperature tracks and remains at least 10C higher than the block temperature, ensuring no evaporation. When the block temperature is 15C or less, the hot-lid will automatically switch off.
Heating and cooling is rapid - less than 8 minutes to heat from ambient to 100C or to cool from 100C to 4C. The internal over temperature protective device automatically stops heating, and switches the hot-lid off, if the block exceeds a temperature of 120C. Set up is very fast using only 2 keys, and it takes just 1 minute to learn how to use the instrument. The unit has 24V DC input power making it suitable for use in a vehicle for transporting samples where temperature needs to be maintained. Can be operated by computer via USB port, enabling multi-segment program setting, software control and more powerful functionality.
PC software controls instrument running. One PC can control several units. Multi-point temperature and time-range settings can be programmed with ease, making the instrument extremely versatile and suitable for a vast range of applications including LAMP, PCA, NASBA, RPA, sample preservation, enzyme reactions, nucleic acid and protein denaturing and electrophoresis preliminary degeneration. The software can inspect and monitor during a run and can print the entire report when the run finishes. The running diary is recorded in real time. Should the instrument become disconnected from the PC during running, the ThermoQ continues the run uninterrupted. The instrument will auto save the last programme, which can be repeated when next used, making it ideal for laboratories running standard protocols time after time.
A protective cover prevents direct contact with the hot metal block making it very safe to use.
The state-of-the-art Thermoelectric module has a long life of at least 50,000 operating hours.
Specifications
Temperature range: 0C - 100C
Temperature display resolution: 0.1C
Heating time: ≤8 min (RT. - 100C)
Cooling time: ≤8 min (100C - 4C)
Temperature uniformity: ≤±0.5C
Temperature control accuracy: ≤±0.2C
Temperature fluctuation: ≤±0.1C
Timing range: - 99 hr 59 min or ∞ (infinite)
Program segment setting function: Yes
Cycle setting function: Yes
Program auto-memory function: Yes
QC report print function: Yes
Maximum segments: 9
Maximum cycles: 99
Hot-lid operating temp:. ≥Block temperature +10C; when block Temperature ≤15C, Hot-lid switches off
Hot-lid heating time: Hot-lid heating rate is faster than block, heating time from RT to 110C ≤10min
Power supply: AC100 ~ 240V 50~60Hz 120W (by power adapter)
Communication interface: USB B Port
Operating state display: Three colour LED display (Red: Heating state, Yellow: Temperature constant state, Green: Cooling state)
Temperature display: Triple LED display
Alarm: Sensor abnormal alarm, red operating lamp flickers; Fault alarm if Hot-lid won’t work
Over Temperature protection: Operates if Temperature above 120 ±5C (Includes Block and Hot-lid)
Dimensions: (WxDxH) 150 x 170 x 145mm
Net weight: ≤2.0kg
Certificate: CE. MET: PICC
Heating and cooling is rapid - less than 8 minutes to heat from ambient to 100C or to cool from 100C to 4C. The internal over temperature protective device automatically stops heating, and switches the hot-lid off, if the block exceeds a temperature of 120C. Set up is very fast using only 2 keys, and it takes just 1 minute to learn how to use the instrument. The unit has 24V DC input power making it suitable for use in a vehicle for transporting samples where temperature needs to be maintained. Can be operated by computer via USB port, enabling multi-segment program setting, software control and more powerful functionality.
PC software controls instrument running. One PC can control several units. Multi-point temperature and time-range settings can be programmed with ease, making the instrument extremely versatile and suitable for a vast range of applications including LAMP, PCA, NASBA, RPA, sample preservation, enzyme reactions, nucleic acid and protein denaturing and electrophoresis preliminary degeneration. The software can inspect and monitor during a run and can print the entire report when the run finishes. The running diary is recorded in real time. Should the instrument become disconnected from the PC during running, the ThermoQ continues the run uninterrupted. The instrument will auto save the last programme, which can be repeated when next used, making it ideal for laboratories running standard protocols time after time.
A protective cover prevents direct contact with the hot metal block making it very safe to use.
The state-of-the-art Thermoelectric module has a long life of at least 50,000 operating hours.
Specifications
Temperature range: 0C - 100C
Temperature display resolution: 0.1C
Heating time: ≤8 min (RT. - 100C)
Cooling time: ≤8 min (100C - 4C)
Temperature uniformity: ≤±0.5C
Temperature control accuracy: ≤±0.2C
Temperature fluctuation: ≤±0.1C
Timing range: - 99 hr 59 min or ∞ (infinite)
Program segment setting function: Yes
Cycle setting function: Yes
Program auto-memory function: Yes
QC report print function: Yes
Maximum segments: 9
Maximum cycles: 99
Hot-lid operating temp:. ≥Block temperature +10C; when block Temperature ≤15C, Hot-lid switches off
Hot-lid heating time: Hot-lid heating rate is faster than block, heating time from RT to 110C ≤10min
Power supply: AC100 ~ 240V 50~60Hz 120W (by power adapter)
Communication interface: USB B Port
Operating state display: Three colour LED display (Red: Heating state, Yellow: Temperature constant state, Green: Cooling state)
Temperature display: Triple LED display
Alarm: Sensor abnormal alarm, red operating lamp flickers; Fault alarm if Hot-lid won’t work
Over Temperature protection: Operates if Temperature above 120 ±5C (Includes Block and Hot-lid)
Dimensions: (WxDxH) 150 x 170 x 145mm
Net weight: ≤2.0kg
Certificate: CE. MET: PICC
Specification
- Brand Bioer Technology Co
- Sterile N
- CE Certified CE Electrical
- Warranty Period 2Y
- Is product classified as dangerous goods? No
- Does the product contain latex? Unspecified
- Temperature Stability 0.1C
- Voltage Rating AC100 ~240V, 50-60Hz, 120W (by power adaptor)
- Operating Temperature 0 - 100C
- Block Capacity 54x 0.5ml tubes
- Heating Time ≤8 min (RT-100C)
- Temperature Display Digital 0.1C resolution
- Temperature Setting Type Push button or USB B port Computer Interface for full programming
- Heating Time 8 min (RT-100C)
Storage Details
- Pack Description Each
- Shipping Condition Ambient
- Storage Condition Ambient
- Pack Length (m) 0.31
- Pack Width (m) 0.2
- Pack Height (m) 0.24
- Pack Weight (kg) 0.00