The GelLITE gel documentation system provides an easy-to-use, cost effective solution for your agarose gel imaging needs.
Provided with a 302nm UV transilluminator you have everything you need to image gels up to 20cm x 20cm in size. This transilluminator is easily removed simply by sliding it our from the main body of the system, allowing for easy access to your gel for DNA extraction. This is coupled with a 5-megapixel camera, providing impressive low light sensitivity and resolution of closely spaced bands. Complete with manual zoom and focus controls giving you full control over your image acquisition to provide the best images possible.
Included free-of-charge is the intuitive genePIX image acquisition software, providing exceptional ease-of-use through its innovative, simplified, application-based approach to image acquisition. This simplified approach can help you speed up your workflow and reduce the complexity and time taken training new users. Also included is the geneQUANT analysis software, complete with automated band detection and report creation, as well as pre-loaded DNA ladder standards, ideal for use in a GLP environment.
The versatility of the system means it can be used for a wide variety of applications, including:
•Fluorescent and visible stained agarose gels
•Spot/colony plate counting
•Coomassie stained protein gels
•GFP Plant Imaging
•Molecular weight analysis of DNA agarose gels and protein gels
•Quantification of DNA in agarose gels
•Autoradiograph imaging
Specification
•Unit Dimensions (cm): 62 x 37.5 x 40
•Material Construction: Powder Coated Steel
•Analysis Software: Included
•Transilluminator Wavelength: 302nm
•Epi White Light: Included
•Transilluminator Size (cm): 20 x 20
•Camera Lens: Manual zoom 6.5 – 39, F1.4
•Sensor Bit-Depth: 12/16 bit
•Emission Filters: Quick change filter tray
•Image Storage Formats: SGD, BMP, TIFF and JPEG
•White Light Table: Included
•Blue Light Table: Blue Light Converter Included
•Sensor Dynamic Range: 3.6-4.8
•21CFR Compliant: Yes
•Advanced Analysis Features: Yes
•Operating System Requirements: Windows
•Safety Features: UV Safety Switch
•CE Marked: Yes
Product Includes: gelLITE Gel documentation system, UV transilluminator, power cable, software USB, instruction manuals and white and blue light conversion screens.
Provided with a 302nm UV transilluminator you have everything you need to image gels up to 20cm x 20cm in size. This transilluminator is easily removed simply by sliding it our from the main body of the system, allowing for easy access to your gel for DNA extraction. This is coupled with a 5-megapixel camera, providing impressive low light sensitivity and resolution of closely spaced bands. Complete with manual zoom and focus controls giving you full control over your image acquisition to provide the best images possible.
Included free-of-charge is the intuitive genePIX image acquisition software, providing exceptional ease-of-use through its innovative, simplified, application-based approach to image acquisition. This simplified approach can help you speed up your workflow and reduce the complexity and time taken training new users. Also included is the geneQUANT analysis software, complete with automated band detection and report creation, as well as pre-loaded DNA ladder standards, ideal for use in a GLP environment.
The versatility of the system means it can be used for a wide variety of applications, including:
•Fluorescent and visible stained agarose gels
•Spot/colony plate counting
•Coomassie stained protein gels
•GFP Plant Imaging
•Molecular weight analysis of DNA agarose gels and protein gels
•Quantification of DNA in agarose gels
•Autoradiograph imaging
Specification
•Unit Dimensions (cm): 62 x 37.5 x 40
•Material Construction: Powder Coated Steel
•Analysis Software: Included
•Transilluminator Wavelength: 302nm
•Epi White Light: Included
•Transilluminator Size (cm): 20 x 20
•Camera Lens: Manual zoom 6.5 – 39, F1.4
•Sensor Bit-Depth: 12/16 bit
•Emission Filters: Quick change filter tray
•Image Storage Formats: SGD, BMP, TIFF and JPEG
•White Light Table: Included
•Blue Light Table: Blue Light Converter Included
•Sensor Dynamic Range: 3.6-4.8
•21CFR Compliant: Yes
•Advanced Analysis Features: Yes
•Operating System Requirements: Windows
•Safety Features: UV Safety Switch
•CE Marked: Yes
Product Includes: gelLITE Gel documentation system, UV transilluminator, power cable, software USB, instruction manuals and white and blue light conversion screens.
Specification
- Brand Alpha Laboratories
- Sterile N
- CE Certified CE Electrical
- Warranty Period 1Y
- Is product classified as dangerous goods? No
- Does the product contain latex? Unspecified
- Voltage Rating 110-220V
- Application Electrophoresis Gel Documentation for fluorescent and colorimetric stained gels
- Length 38cm
- Height 62cm
- Width 40cm
Storage Details
- Pack Description Each
- Shipping Condition Ambient
- Storage Condition Ambient
- Pack Length (m) 0.4
- Pack Width (m) 0.4
- Pack Height (m) 0.7
- Pack Weight (kg) 0.00
Literature
You may also be interested in
1 ? activePage - 1 : activePage" >Prev
Next