This product is for Professional Use only and not for sale to the general public for home use.
Please log in with a business account to purchase.

Erythromycin Allergen – for use in combination with the BÜHLMANN CAST® assays
Product code: BAG2-CERY
CE Verified: IVDR
Contact us
This is not a regular stock item and therefore not subject to our standard delivery schedule. Please contact us on +44 (0) 2380 483000 for advice on expected delivery date.
Product Information
BÜHLMANN CAST® Allergens are optimized for in vitro Basophil Activation using BÜHLMANN CAST® assays: CAST® ELISA (EK-CAST) and Flow CAST® (FK-CCR).
CAST® drug allergens. Before using it in CAST® assays, they are to be reconstituted with test specific Stimulation Buffer: CAST® ELISA: B-CAST-STB and Flow CAST®: B-CCR-STB.
Add 250μl Stimulation Buffer into the vial and vortex until the allergen has completely dissolved. For some allergens an additional dilution with Stimulation Buffer is recommended.
Remark: Some individuals react positive either at high or at low allergen concentrations, whereas others react positive over a broad range of concentration.
Storage and Stability: Unopened CAST® Allergens are to be stored Store at ≤ -20°C. Do not use the reagents beyond the expiration date printed on the labels.
Important: Reconstituted or diluted allergens must not be stored and used again!
Blood samples must be drawn for CAST® assays before carrying out a skin test or in vivo provocation with the presumed allergen as in vivo exposure to an allergen can cause an activation of the leucocytes.
Limitations: A negative CAST® assay result for a specific allergen does not exclude potential (even serious) clinical symptoms. Individuals who developed „allergic“ reactions towards protein or drug allergens in the past and whose CAST® assay was negative, should thus be verified with additional methods like the in vivo provocation or skin test before a drug is administered or a patient is exposed to the allergen.
Concentrations and cut-off: Concentrations and cut-off of these allergen groups were optimised regarding maximum specificity and sensitivity. Concentrations to be used in the test and cut-off of individual allergens are reported in the specifications of the allergens. For Flow CAST®, BÜHLMANN recommends the application of the stimulation index (SI) as an additional diagnostic criterion. The SI is defined as the ratio of allergen specific basophil activation and background activation.
Remarks: In order to apply allergen specific cut-offs, QC criteria published in the CAST® instructions must be fulfilled. Cut-offs should serve only as recommendations. Clinically defined cut-offs should be established by each laboratory or through clinical studies.
CAST® drug allergens. Before using it in CAST® assays, they are to be reconstituted with test specific Stimulation Buffer: CAST® ELISA: B-CAST-STB and Flow CAST®: B-CCR-STB.
Add 250μl Stimulation Buffer into the vial and vortex until the allergen has completely dissolved. For some allergens an additional dilution with Stimulation Buffer is recommended.
Remark: Some individuals react positive either at high or at low allergen concentrations, whereas others react positive over a broad range of concentration.
Storage and Stability: Unopened CAST® Allergens are to be stored Store at ≤ -20°C. Do not use the reagents beyond the expiration date printed on the labels.
Important: Reconstituted or diluted allergens must not be stored and used again!
Blood samples must be drawn for CAST® assays before carrying out a skin test or in vivo provocation with the presumed allergen as in vivo exposure to an allergen can cause an activation of the leucocytes.
Limitations: A negative CAST® assay result for a specific allergen does not exclude potential (even serious) clinical symptoms. Individuals who developed „allergic“ reactions towards protein or drug allergens in the past and whose CAST® assay was negative, should thus be verified with additional methods like the in vivo provocation or skin test before a drug is administered or a patient is exposed to the allergen.
Concentrations and cut-off: Concentrations and cut-off of these allergen groups were optimised regarding maximum specificity and sensitivity. Concentrations to be used in the test and cut-off of individual allergens are reported in the specifications of the allergens. For Flow CAST®, BÜHLMANN recommends the application of the stimulation index (SI) as an additional diagnostic criterion. The SI is defined as the ratio of allergen specific basophil activation and background activation.
Remarks: In order to apply allergen specific cut-offs, QC criteria published in the CAST® instructions must be fulfilled. Cut-offs should serve only as recommendations. Clinically defined cut-offs should be established by each laboratory or through clinical studies.
Specification
- Brand BÜHLMANN
- Sterile N
- CE Certified IVDR
- Warranty Period Standard Terms Apply
- Is product classified as dangerous goods? No
- Does the product contain latex? Unspecified
- UK CA Type IVDR
- Shelf Life 3 years
- Host Null
- Purity Null
- Application Allergy testing
- Form Null
- Specificity Null
- Species Reactivity Null
- Concentration Varies
- Marketed Grade Null
- Preparation Form Frozen Liquid
Storage Details
- Shipping Condition Dry Ice
- Storage Condition -20
- Storage Conditions (Max Temp) -20
- Storage Conditions (Min Temp) -20
- Storage Conditions (Humidity) 1
- Pack Length (m) 0.05
- Pack Width (m) 0.018
- Pack Height (m) 0.046
- Pack Weight (kg) 0.00