Faecal calprotectin sample preparation device Roche Smart-Prep. No extraction buffer. For use with BÜHLMANN assays. Box of 50
Pack size: 50 Tubes
Product code: B-CAL-RD

This product is for Professional Use only and not for sale to the general public for home use. Please log in with a business account to purchase.

This product is not available for direct sale from this website to countries outside of the UK.

Please Enquire

Faecal calprotectin sample preparation device Roche Smart-Prep. No extraction buffer. For use with BÜHLMANN assays. Box of 50

The Roche Smart-Prep faecal sample preparation device is to facilitate and simplify the extraction process in preparation for Calprotectin assay. Faecal sample is placed in the tube cap using a disposable spatula and then the sealed tube is vortexed with BÜHLMANN extraction buffer to extract the calprotectin. Each pack contains 50 extraction tubes and spatulas.
Brand
BÜHLMANN
Sterile
No
CE Certified
CE IVD
Warranty Period
Standard Terms Apply
Contents
50 polypropylene faecal sample collection and extraction tubes and caps. 50xdisposable spatula. Add extraction buffer to tube before use. For use with BÜHLMANN fCAL® ELISA or Quantum Blue® Calprotectin assays.
Size
Pack of 50. Sample collection chamber holds ~85mg of faecal material.
Detected chemical
Faecal calprotectin
UNSPSC Description
Chemistry test kits or supplies
UNSPSC Code
41116104
NHS eClass Description
Chemical & Biochemical Diagnostic Products
NHS eClass Code
HHB
Pack Description
50 Tubes
Shipping Condition
Ambient
Storage Condition
Ambient
Pack Length (m)
0.22
Pack Width (m)
0.16
Pack Height (m)
0.12
Pack Weight (Kg)
0.1000

Write your own review

You're reviewing:

Faecal calprotectin sample preparation device Roche Smart-Prep. No extraction buffer. For use with BÜHLMANN assays. Box of 50



How do you rate this product? *


 
1 1 star
2 2 star
3 3 star
4 4 star
5 5 star
Quality
Ease of Use
Value for Money

  • 10 Years of Calprotectin Testing in the UK

    • PDF size: 8.40KB
    • Updated on: 04/07/2018

    Future-proof Your Calprotectin Testing

    Open File
  • BÜHLMANN Calprotectin assays, used by hundreds, trusted by thousands……

    • PDF size: 868.39KB
    • Updated on: 04/07/2018

    Reference List

    Open File
  • Calprotectin Clinical Publications

    • PDF size: 10.55KB
    • Updated on: 04/07/2018

    Open File
  • Calprotectin Revolution and Evolution

    • PDF size: 12.37KB
    • Updated on: 04/07/2018

    Open File
  • Diagnostics for Digestive Health Management

    • PDF size: 10.06MB
    • Updated on: 07/12/2018

    Open File
  • NICE Diagnostics Guidance 11 - Calprotectin

    • PDF size: 4.62KB
    • Updated on: 04/07/2018

    Faecal calprotectin diagnostic tests for inflammatory diseases of the bowel

    Open File
  • Three simple tests could save the NHS at least £6.9 billion

    • PDF size: 10.01KB
    • Updated on: 04/07/2018

    A report from BIVDA and Innovate UK identifies that calprotectin testing could save the NHS £65 million.

    Open File
  • When is the Best Time for Sampling Faeces for Calprotectin Analysis?

    • PDF size: 11.44KB
    • Updated on: 04/07/2018

    Open File
  • Same faeces, same lab, different methods and some different calprotectin results

    • PDF size: 9.42KB
    • Updated on: 03/08/2018

    Lythgoe and McCann;Stockport NHS - Poster BSG 2016

    Open File
  • CALEX® CAP, A NOVEL STOOL COLLECTION AND EXTRACTION DEVICE: PERFORMANCE ANALYSIS AND STABILITY OF CALPROTECTIN IN STOOL EXTRACTS

    • PDF size: 10.80KB
    • Updated on: 03/08/2018

    BÜHLMANN Laboratories AG, University of Applied Sciences, Muttenz; ROTHEN Medizinische Laboratorien AG, - Switzerland: Poster Euromedlab, June 2015

    Open File
  • Evaluation of BÜHLMANN CALEX® Cap Stool Extraction Devices for the extraction of faecal calprotectin

    • PDF size: 8.55KB
    • Updated on: 03/08/2018

    Sukhbir Kaur, Clare Ford, Rousseau Gama Department of Clinical Chemistry, New Cross Hospital

    Open File
  • False Positive Calprotectin User Report

    • PDF size: 14.05KB
    • Updated on: 04/07/2018

    User Report Published in Leading Edge - Autumn 2016

    Open File
  • Faecal calprotectin in patients with suspected colorectal cancer: a diagnostic accuracy study

    • PDF size: 8.64KB
    • Updated on: 13/07/2018

    Turvill J et al., Department of Gastroenterology, York Teaching Hospital NHS Foundation Trust, Online First 2016

    Open File

Contact

Please contact us if you require further information about this product.




Your request will be forwarded to the relevant department to assist with your enquiry.
By clicking 'Send Enquiry' you are authorising Alpha Laboratories to process your information and use it to contact you so that we may respond to your request, as well as to communicate with you regarding our products and services.

Submitting your details indicates that you agree to our Privacy Policy.

* Required Fields