Diagnostic reagent for quantitative in vitro determination of triglycerides in human serum
or plasma, range 0.02 – 11.3 mmol/L.
Product code: D96388
Pack Size: 5x50ml
CE Verified: CE IVD
Contact us
This is not a regular stock item and therefore not subject to our standard delivery schedule. Please contact us on +44 (0) 2380 483000 for advice on expected delivery date.
Product Information
Diagnostic reagent for quantitative in vitro determination of triglycerides in human serum
or plasma on photometric systems, measuring range 0.02 – 11.3 mmol/L.
naturally occurring lipids. They are transported in plasma bound to apolipoproteins
forming very low density lipoproteins (VLDL) and chylomicrons. Measurement of
triglycerides is used in screening of the lipid status to detect atherosclerotic risks and in
monitoring of lipid lowering measures. Studies have shown that elevated triglyceride
concentrations combined with increased low density lipoprotein (LDL) concentrations
constitute an especially high risk for coronary heart disease (CHD). High triglyceride
levels also occur in various diseases of liver, kidneys and pancreas.
This is a colorimetric, enzymatic, endpoint reaction. Determination of triglycerides after enzymatic splitting with lipoprotein lipase. Indicator is quinoneimine which is generated from 4-aminoantipyrine and 4-chlorophenol by hydrogen peroxide under the catalytic action of peroxidase.
Each kit contains 5 x 50ml (Good´s Buffer, 4 Chlorophenol, Mg2+, ATP, Glycerolkinase (GK), Peroxidase (POD), Lipoprotein lipase (LPL), 4-Aminoantipyrine, Glycerol-3-phosphate-oxidase (GPO)) and 1 x 50ml R2 (2-Cresolphtalein complexone, 8-Hydroxychinoline and Hydrochloric acid). Reagent is provided ready-to-use.
The recommended calibrator is the Diacal Auto (D98485SV).
Suggested QC are the Diacon Control Serum (D98481SV & D98482SV).
or plasma on photometric systems, measuring range 0.02 – 11.3 mmol/L.
naturally occurring lipids. They are transported in plasma bound to apolipoproteins
forming very low density lipoproteins (VLDL) and chylomicrons. Measurement of
triglycerides is used in screening of the lipid status to detect atherosclerotic risks and in
monitoring of lipid lowering measures. Studies have shown that elevated triglyceride
concentrations combined with increased low density lipoprotein (LDL) concentrations
constitute an especially high risk for coronary heart disease (CHD). High triglyceride
levels also occur in various diseases of liver, kidneys and pancreas.
This is a colorimetric, enzymatic, endpoint reaction. Determination of triglycerides after enzymatic splitting with lipoprotein lipase. Indicator is quinoneimine which is generated from 4-aminoantipyrine and 4-chlorophenol by hydrogen peroxide under the catalytic action of peroxidase.
Each kit contains 5 x 50ml (Good´s Buffer, 4 Chlorophenol, Mg2+, ATP, Glycerolkinase (GK), Peroxidase (POD), Lipoprotein lipase (LPL), 4-Aminoantipyrine, Glycerol-3-phosphate-oxidase (GPO)) and 1 x 50ml R2 (2-Cresolphtalein complexone, 8-Hydroxychinoline and Hydrochloric acid). Reagent is provided ready-to-use.
The recommended calibrator is the Diacal Auto (D98485SV).
Suggested QC are the Diacon Control Serum (D98481SV & D98482SV).
Specification
- Brand Dialab
- Sterile N
- CE Certified CE IVD
- Warranty Period Standard Terms Apply
- Sterilisation Method Not Applicable
- Is product classified as dangerous goods? No
- Does the product contain latex? Unspecified
- CAS Number NULL
- Composition Single Liquid Stable Reagent
- Concentration Range 0.02 – 11.3 mmol/L
- Detection Method Colorimetric, enzymatic, end-point
- Diagnostic Target Human serum or plasma triglycerides
- Form 5x50ml
- Marketed Grade CE IVD
Storage Details
- Pack Description 5x50ml
- Shipping Condition Ambient
- Storage Condition Fridge
- Pack Length (m) 0.2
- Pack Width (m) 0.15
- Pack Height (m) 0.12
- Pack Weight (kg) 3.00