The Clarit-E Electroblotting Systems include both modules required for Slab Gel Electrophoresis and Electroblotting and accessories, to provide a complete Mini, Mini Wide or Maxi gel casting, running and electroblotting system. The electroblotting module includes three inter-locking cassettes and six fibre pads.
A high intensity current is generated by coiled platinum electrodes. These in conjunction with the advanced cooling features allow rapid electroblotting in as little as one hour.
Ordering Information
| Catalogue Number |
Description |
| EL2410 |
Complete System for Mini Vertical (10 x 10cm) Electrophoresis & Blotting comprising:
1x Clarit-E Mini Vertical Unit screw version which includes: 2x2mm thick notched glass plates, 2x2mm thick plain glass plates with 1mm thick bonded spacers, 1x dummy plate, 2x combs (1mm thick 12 samples), 1x casting base, silicone mat, cooling pack. plus: 1x Electroblotting Module which includes: internal electroblotting module, 3x compression cassettes for gel sizes up to 10x10cm and 6x fibre pads.
|
| EL2400 |
Complete System for Mini Vertical (10 x 10cm) Electrophoresis & Blotting comprising:
1x Clarit-E Mini Vertical Unit clamp version which includes: 2x2mm thick notched glass plates, 2x2mm thick plain glass plates with 1mm thick bonded spacers, 1x dummy plate, 2x combs (1mm thick 12 samples), 1x casting base, silicone mat, cooling pack. plus: 1x Electroblotting Module which includes: internal electroblotting module, 3x compression cassettes for gel sizes up to 10x10cm and 6x fibre pads.
|
| EL2450 |
Complete System for Mini Wide Vertical (20 x 10cm) Electrophoresis & Blotting comprising:
1x Clarit-E Mini Wide Vertical Unit which includes: 2x4mm thick notched glass plates, 2x4mm thick plain glass plates with 1mm thick bonded spacers, 1x dummy plate, 2x combs (1mm thick, 24 samples), 1x casting base, silicone mat, cooling pack. plus: 1x Wide Electroblotting Module (20x10cm) which includes: internal electroblotting module, 3x compression cassettes for gel sizes up to 20x10cm and 6x fibre pads.
|
| EL2500 |
Complete System for Maxi Vertical (20 x 20cm) Electrophoresis & Blotting comprising:
1x Clarit-E Maxi Vertical Unit which includes: 2x4mm thick notched glass plates, 2x4mm thick plain glass plates with 1mm thick bonded spacers, 1x dummy plate, 2x combs (1mm thick 24 samples), 1x casting base, silicone mat, cooling pack. plus: 1x Electroblotting Module comprising: internal electroblotting module, 3x compression cassettes for gel sizes up to 20x20cm and 6x fibre pads.
|
Clarit-E Electroblotting
- Ideal for Western blotting of proteins
- Open design, rigid cassettes for maximum current transfer
These stand-alone, complete units for electroblotting, Mini, Mini Wide and Maxi formats, include Clarit-E tank and lid, electroblotting insert, cassettes and fibre pads. Units are interchangeable with Clarit-E slab and tube gel inserts. Hinged rigid cassettes allow rapid set up and convenience and ensure even contact between the gel and membrane is maintained.
Ordering Information
| Catalogue Number |
Description |
| EL2402 |
Clarit-E Blot Mini, 10 x 10cm System including tank and lid, 3 cassettes, 6 fibre pads, cooling pack |
| EL2452 |
Clarit-E Blot Mini wide, 20 x 10cm System including tank and lid, 3 cassettes, 6 fibre pads, cooling pack |
| EL2502 |
Clarit-E Blot Maxi, 20 x 20cm System including tank and lid, 3 cassettes, 6 fibre pads, cooling pack |
Accessories
| EL2034 |
Clarit-E Blot Mini Insert – includes 3 cassettes and 6 fibre pads. |
| EL2036 |
Clarit-E Blot Mini Cassette |
| EL2038 |
Fibre pads - pk/6 |
| EL2114 |
Clarit-E Blot Mini Wide Insert - includes 3 cassettes and 6 fibre pads. |
| EL2106 |
Clarit-E Blot Mini Wide Cassette |
| EL2458 |
Fibre pads - pk/6 |
| EL2134 |
Clarit-E Blot Maxi Insert – includes 3 cassettes and 6 fibre pads. |
| EL2136 |
Clarit-E Blot Maxi Cassette |
| EL2138 |
Fibre pads - pk/6 |
Clarit-E Tank Sub Electroblotters.
-
Ideal for wet electroblotting of proteins - Western blotting
- Up to five gel blot cassettes utilised at any one time
- Hinged cassettes for added convenience
- Accommodates gel thicknesses from 0.25 up to 3mm
Designed primarily for wet electroblotting of proteins, Tank Sub Electroblotters offer a combination of increased capacity with economy saving features. Both units, Mini 10 x 10cm and Maxi 20 x 20cm, have increased capacity over standard systems with up to five gel blot cassettes utilised at any one time. This is especially useful in high throughput laboratories.
A uniform electric field is provided by a high intensity coiled electrode and ensures uniform transfer across the blot surface. The cassette’s open architecture ensures the maximum blot area allows direct transfer of current. Its rigid construction ensures contact between the gel and membrane is retained throughout the blot and an even pressure is maintained. These units are compatible with magnetic stirrers to aid heat dispersal and prevent pH drifts in the buffer due to incomplete buffer mixing. Each system includes a cooling pack to further enhance transfer efficiency by removing excess heat. This also saves on buffer for added economy.
Technical Specifications
| Unit dimensions (W x D x H) |
Mini
Maxi
|
19 x 13 x 19cm
24 x 16 x 26cm
|
| Max. sample, Capacity |
Mini
Maxi
|
5 Blots, 10 x 10cm
5 Blots, 20 x 20cm
20 Blots, 10 x 10cm
|
| Buffer volume |
Mini:
Maxi:
|
Min 1000ml; Max 1500ml
Min 4300ml; Max 6000ml
|
Ordering Information
| Catalogue Number |
Description |
| EL2412 |
Electro Blot Mini, 10 x 10cm System for five cassettes, with tank and lid, 5x cassettes, 12x fibre pads and cooling pack |
| EL2512 |
Electro Blot Maxi, 20 x 20cm System for five cassettes, with tank and lid, 5x cassettes, 12x fibre pads and cooling pack |
| EL2036 |
Tank Blot Mini Cassette |
| EL2038 |
Fibre pads - pk/6 |
| EL2136 |
Tank Blot Maxi Cassette |
| EL2138 |
Fibre pads - pk/6 |
Clarit-E Semi Dry Electroblotters
-
Rapid transfer times
- Western, Southern and Northern Blots
- Economic Transfers due to very low buffer volumes
- Screw down lid - Gels from 0.25 up to 10mm thick can be blotted
- Uniform heat dispersion
- Long life electrodes
These Semi Dry Blotters offer rapid transfer times for DNA, RNA and protein blotting - typically 15 to 30 minutes. All units can be used for all types of blotting: western, southern and northern via uncomplicated buffer and set up procedures and are compatible with gel thicknesses from 0.25 up to 10mm without the need for additional equipment. Each unit is compatible with their respective Clarit-E vertical gel system. Semi Dry Blotting has the added benefit of economic transfers due to very low buffer volumes – typically only a few millilitres of buffer are required per transfer. These Semi-Dry Blotters utilise a screw down lid, which secures the blot sandwich and allows complete control of pressure ensuring even transfer. The electrodes, comprising platinum coated anode and stainless steel cathode, will exhibit practically no corrosion and so provide many years of trouble free use. Uniform heat dispersion across the blot sandwich ensures stable transfer times and no heat induced sample loss or transfer distortions. Being translucent, it allows viewing of the blot sandwich to ensure correct positioning and transfer is occurring correctly. Electrode plates are fully separated to prevent arching or damage.
Technical specifications
| Unit dimensions (W x L x H) |
Mini
Maxi
Maxi Plus
Maxi Long
|
16 x 16 x 7cm
26 x 26 x 7cm
39 x 51 x 7cm
26 x 56 x 7cm
|
| Max. sample capacity |
Mini
Maxi
Maxi Plus
Maxi Long
|
1 Blot, 10 x 10cm
1 Blot, 20 x 20cm
4 Blots, 10 x 10cm
1 Blot, 35 x 45cm
1 Blot, 20 x 50cm
|
| Buffer volume |
Mini
Maxi
Maxi Plus
Maxi Long
|
5ml
20ml
75ml
50ml
|
Ordering information
| Catalogue Number |
Description |
| EL2460 |
Semi Dry Mini Blotter 10 x 10cm system |
| EL2465 |
Semi Dry Maxi Blotter 20 x 20cm system |
| EL2470 |
Semi Dry Maxi Plus Blotter 33 x 45cm system |
| EL2475 |
Semi Dry Maxi Long Blotter 20 x 50cm system |
Text Box: Insert pic F:\Suppliers\Cleaver Scientific_CLE400\Product data\Presentations\Electrophoresis Catalogue\Fonts and Pictures 1\CapBlot1.tif
Clarit-E Capillary Blotting
-
Permanent wick with optimized capillary action
- Efficient transfer of high and low molecular weight fragments
- Fast, easy set-up
- DNA transfer in 2 hours or less; RNA transfer in 3 hours or less
- Floating lid ensures even pressure without gel compression
These Capillary Blotting systems offer a contained unit for southern and northern blotting. These units incorporate optimized permanent wicks, which eliminate the requirement for overlapping wicks, offering greater consistency.
The porous polyethylene platform draws up transfer buffer faster than traditional systems allowing for faster transfer times.
Side by side transfer of multiple gels can be performed in a single set up.
Available in 15 x 26cm and 28 x 26cm formats.
Principle:
Through capillary action, the buffer travels from the reservoir to the absorbent towelling via the porous supports, permanent wick, gel and membrane. This action optimises the transfer of low and high Molecular Weight DNA/RNA from gel to membrane without mechanical damage to even the thinnest of gels.
Technical Specifications
| Unit dimensions (W x L x H) |
Mini
Maxi
|
30 x 30 x 10cm
42 x 30 x 10cm
|
Ordering Information
| Catalogue Number |
Description |
| EL2480 |
Capillary Blotting Unit (28cm x 26cm) |
| EL2485 |
Capillary Blotting Unit (15cm x 26cm) |
Clarit-E dot and slot blotters
-
Low cost
- Simple construction
- Easy assembly
- Four sample configurations
- Alphanumeric sample identification
Four different sample number size and style of Hybridisation Manifold are offered:- two types of dot blotter and two types of slot blotter.
Typical applications include clone screening with DNA / RNA probes in Southern / Northern blots and immunological screening with antibodies in western blots.
The units incorporate precision lapped surfaces to ensure uniform blotting membrane contact and a leak proof gasket. These prevent lateral transfer of samples – smudging – by ensuring that a complete vacuum is formed. Six thumbscrews ensure even and tight sealing for fast sample suck down.
Dot blotters are available in 48 and 96 well versions and slot blotters in 24 and 48 well.
Technical Specifications
| Model |
EL2448 |
EL2496 |
EL2524 |
EL2548 |
| Configuration |
3 x 16 |
8 x 12 |
2 x 12 |
3 x 16 |
| Size of well |
6mm diameter
12mm deep
|
6mm diameter
12mm deep
|
6 x 0.5mm
12mm deep
|
6 x 0.5mm
12mm deep
|
| Vacuum required |
600mg Hg 0.8 BAR with cold trap |
| Unit dimensions |
60 x 95 x 100cm |
60 x 105 x 140cm |
60 x 74 x 83cm |
60 x 95 x 100cm |
| Membranes size required |
12.1 x 4.4cm |
11 x 7.4cm |
12.1 x 4.4cm |
12.1 x 4.4cm |
Ordering Information
| Catalogue Number |
Description |
| EL2448 |
48 well Dot Blot Manifold, 3 x 16 array |
| EL2496 |
96 well Dot Blot Manifold, 8 x 12 array |
| EL2524 |
24 well Slot Blot Manifold, 2 x 12 array |
| EL2548 |
48 well Slot Blot Manifold, 3 x 16 array |